LONGDE / FOUR CHEMICAL TESTS
Longde metal sample
passes four chemical tests
The sample passed all four tests: cadmium, lead, arsenic and nickel release.
Intertek Guangzhou received silver-colored metal samples on January 21, 2022, and issued report GZHT91093676 on February 16. The report lists zinc as the material, LD20618 as the reference and adult use as the category.
The report lists YOKAI ORNAMENT CO.,LTD., a former name of Longde Hardware, as the applicant. It shows the previous address in Hetian Second Industrial Zone, Hetian Village, Houjie, Dongguan. It lists HP as the brand and Wolverine World Wide Inc. as the buyer.
View all four results ↓
01Submitted samples
The applicant specified the tests on the silver-colored zinc alloy samples.
The report describes the sample as “Metal In Silver,” lists the color as “Silver” and the pattern as “Metal.” It names China as the country of origin and Merry Huang as the contact.
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch issued the report. Guiliang Dong, Senior Lab Manager, signed it.

02Cadmium, lead and arsenic
All three total concentrations were within their limits and passed.
Cadmium was not detected (detection limit 5 mg/kg, test limit 40 ppm). Lead measured 11 ppm (detection limit 10 ppm, test limit 40 ppm). Arsenic was not detected (detection limit 10 ppm, test limit 100 ppm). The report treats ppm as equivalent to mg/kg and defines ND as not detected.
All three tests used acid digestion and inductively coupled argon plasma spectroscopy to measure total content. The report states that the client requested the lead and arsenic tests. Its final page describes the tested component as “Silver Color Metal.”
- Report number
- GZHT91093676
- Cadmium
- Not detected · Limit 40 ppm
- Lead
- 11 ppm · Limit 40 ppm
- Arsenic
- Not detected · Limit 100 ppm

03Nickel release
No nickel release was detected in either the direct or the simulated wear test. Both passed.
One group was tested with reference to EN 1811:2011+A1:2015. The second underwent simulated wear with reference to EN 12472:2020 and was then measured using EN 1811:2011+A1:2015. Each group had three specimens, with a specimen area of 30.0 cm² and 30.0 mL of test solution.
All six results were ND. The detection limit was 0.05 μg/cm² per week and the required limit was 0.5 μg/cm² per week. The report records “Pass.”

Source: Intertek Guangzhou report GZHT91093676, February 16, 2022. The samples arrived and testing began on January 21, 2022. The sample information and four results on this page apply to the submitted silver-colored zinc alloy components.
Updated: